Close Go back Collapse all sections
Process Data set: Venkon - size 67 (en) en

Key Data Set Information
Location GLO
Geographical representativeness description Global with production site in Germany.
Reference year 2023
Name
Venkon - size 67
Use advice for data set There is no use advice for the data set.
Technical purpose of product or process The product is mainly used in office spaces & buildings for cooling and heating purposes.
Classification
Class name : Hierarchy level
  • The International EPD System: Construction products, Infrastructure & buildings
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Time representativeness
Data set valid until 2028
Technological representativeness
Technology description including background system The cooling and heat outputs have been calculated in line with DIN EN 1397 "Water-air fan convectors, test methods for establishing the performance". The specific requirements for cooling and heating mode are taken into account in DIN EN 1397. Fan coils are very often used in acoustically sensitive areas. The units have therefore been optimised in terms of sound emissions. The acoustic data were recorded in accordance with the provisions of DIN EN 16583 by DIN EN ISO 3744 and DIN EN ISO 3741 in the Kampmann GmbH & Co. KG laboratories.
Pictogram of technology

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 968
  • 0.707
  • 0.394
  • ND
  • 0.273
  • ND
  • 5.99
  • ND
  • 229
  • ND
  • 0
  • 0.0534
  • 0.0408
  • 0.171
  • -453
Input
  • 0.788
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 969
  • 0.707
  • 0.394
  • ND
  • 0.273
  • ND
  • 5.99
  • ND
  • 229
  • ND
  • 0
  • 0.0534
  • 0.0408
  • 0.171
  • -453
Input
  • 4.12E+3
  • 93.9
  • 12
  • ND
  • 0.943
  • ND
  • 65.3
  • ND
  • 1.14E+3
  • ND
  • 0
  • 3.65
  • 0.694
  • 2.07
  • -1.66E+3
Input
  • 6.86
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 4.13E+3
  • 93.9
  • 12
  • ND
  • 0.943
  • ND
  • 65.3
  • ND
  • 1.14E+3
  • ND
  • 0
  • 3.65
  • 0.694
  • 2.07
  • -1.66E+3
Input
  • 0.358
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 3.04
  • 0.0112
  • 0.014
  • ND
  • 0.00278
  • ND
  • 0.0711
  • ND
  • 0.434
  • ND
  • 0
  • 0.000726
  • 0.0057
  • 0.023
  • -0.942
Output
  • 0
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 10.23
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 31.9
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 4.93
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 4.09E+3
  • 93.9
  • 12
  • ND
  • 0.938
  • ND
  • 65.3
  • ND
  • 1.14E+3
  • ND
  • 0
  • 3.65
  • 0.694
  • 2.07
  • -1.66E+3
  • 33.5
  • 0.00000705
  • 0.00000224
  • ND
  • 4.01E-7
  • ND
  • 0.000945
  • ND
  • 0.000126
  • ND
  • 0
  • 6.73E-7
  • 2.15E-7
  • 2.54E-7
  • -0.0186
  • 3.43
  • 0.0281
  • 0.00239
  • ND
  • 0.000287
  • ND
  • 0.0796
  • ND
  • 0.164
  • ND
  • 0
  • 0.000596
  • 0.00163
  • 0.000624
  • -1.96
  • 0.00000614
  • 1.21E-7
  • 5.71E-9
  • ND
  • 2.95E-9
  • ND
  • 5.9E-8
  • ND
  • 6.92E-7
  • ND
  • 0
  • 5.47E-9
  • 7.57E-9
  • 2.49E-9
  • -0.00000334
  • 0.28
  • 0.000231
  • 0.000179
  • ND
  • 0.0000519
  • ND
  • 0.00622
  • ND
  • 0.109
  • ND
  • 0
  • 0.0000178
  • 0.0000203
  • 0.00000927
  • -0.162
  • 0.366
  • 0.0107
  • 0.000543
  • ND
  • 0.0000865
  • ND
  • 0.00622
  • ND
  • 0.0538
  • ND
  • 0
  • 0.000162
  • 0.000806
  • 0.000244
  • -0.159
  • 3.95
  • 0.114
  • 0.00499
  • ND
  • 0.000622
  • ND
  • 0.0737
  • ND
  • 0.39
  • ND
  • 0
  • 0.00167
  • 0.00851
  • 0.00264
  • -1.83
  • 3.1E+2
  • 6.8
  • 0.573
  • ND
  • 0.0619
  • ND
  • 3.78
  • ND
  • 76.4
  • ND
  • 0
  • 0.241
  • 12.2
  • 0.0896
  • -125
  • -0.599
  • 0.00261
  • 0.00291
  • ND
  • -0.00507
  • ND
  • 0.0139
  • ND
  • 7.78
  • ND
  • 0
  • 0.000192
  • 0.114
  • 0.00671
  • -0.277
  • 305
  • 6.78
  • 0.57
  • ND
  • 0.059
  • ND
  • 3.75
  • ND
  • 75.2
  • ND
  • 0
  • 0.241
  • 12.2
  • 0.0891
  • -123
  • 2.31
  • 0.00146
  • 0.000392
  • ND
  • 0.0024
  • ND
  • 0.0101
  • ND
  • 0.125
  • ND
  • 0
  • 0.000117
  • 0.0000354
  • 0.0000415
  • -1.51
  • 307
  • 6.79
  • 0.573
  • ND
  • 0.0563
  • ND
  • 3.77
  • ND
  • 83.1
  • ND
  • 0
  • 0.241
  • 12.3
  • 0.0959
  • -125
  • 1.43
  • 0.0393
  • 0.00211
  • ND
  • 0.000175
  • ND
  • 0.0233
  • ND
  • 0.108
  • ND
  • 0
  • 0.000973
  • 0.0023
  • 0.000933
  • -0.694
  • 59.4
  • 0.258
  • 0.287
  • ND
  • 0.0353
  • ND
  • 1.7
  • ND
  • 2.78
  • ND
  • 0
  • 0.0174
  • 0.0301
  • 0.0579
  • -27.1

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Eco-toxicity - freshwater (ETP-fw) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Human toxicity, cancer effect (HTP-c) 2
  • 0.00000112
  • 1.45E-9
  • 5.51E-9
  • ND
  • 3.27E-11
  • ND
  • 1.93E-8
  • ND
  • 1.63E-8
  • ND
  • 0
  • 1.07E-10
  • 1.67E-9
  • 1.89E-8
  • -6.01E-7
Human toxicity, non-cancer effects (HTP-nc) 2
  • 0.0000312
  • 7.26E-8
  • 2.58E-8
  • ND
  • 7.49E-10
  • ND
  • 9.51E-7
  • ND
  • 5.02E-7
  • ND
  • 0
  • 2.61E-9
  • 1.07E-8
  • 0.00000129
  • -0.0000209
Ionizing radiation, human health (IRP) 1
  • 37.8
  • 0.063
  • 0.0282
  • ND
  • 0.00888
  • ND
  • 0.342
  • ND
  • 18.1
  • ND
  • 0
  • 0.00461
  • 0.0028
  • 0.00838
  • -19
Land use related impacts/Soil quality (SQP) 2
  • 2.32E+3
  • 36.8
  • 1.24
  • ND
  • 0.495
  • ND
  • 29.3
  • ND
  • 162
  • ND
  • 0
  • 3.71
  • 0.248
  • 4.46
  • -589
Particulate Matter emissions (PM) 2
  • 0.0000249
  • 2.55E-7
  • 4.37E-8
  • ND
  • 2.69E-9
  • ND
  • 3.09E-7
  • ND
  • 7.3E-7
  • ND
  • 0
  • 2.38E-8
  • 1.31E-8
  • 1.36E-8
  • -0.0000103