Close Go back Collapse all sections
Process Data set: PowerKon LT - size 2 (en) en

Key Data Set Information
Location DE
Geographical representativeness description Since the installation scenario is for Germany, the geopgraphical scope is representative for Germany.
Reference year 2024
Name
PowerKon LT - size 2
Use advice for data set There is no use advice for the data set.
Technical purpose of product or process The product is used for heating and cooling requirements for buildings.
Classification
Class name : Hierarchy level
  • The International EPD System: Construction products, Infrastructure & buildings
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system Kampmann GmbH & Co. KG produces the fan coil PowerKon LT in three different sizes. This EPD is specific for PowerKon LT - size 2*. The product can operate in different switching stages. The environmental performance of different configurations was investigated, and the results of this study are provided for the use at maximum switching stage.
Pictogram of technology

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Maintenance
B2
Repair
B3
Replacement
B4
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 223
  • 0.313
  • 18.4
  • 0.283
  • 0.11
  • 2.75
  • 116
  • 0
  • 0.0212
  • 0.165
  • 0.09
  • -87.9
Input
  • 18.3
  • 0
  • -18.3
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 241
  • 0.313
  • 0.134
  • 0.283
  • 0.11
  • 2.75
  • 116
  • 0
  • 0.0212
  • 0.165
  • 0.09
  • -87.9
Input
  • 1.33E+3
  • 46.1
  • 5.05
  • 1
  • 0.408
  • 25.7
  • 574
  • 0
  • 1.45
  • 1.41
  • 1.26
  • -374
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1.33E+3
  • 46.1
  • 5.05
  • 1
  • 0.408
  • 25.7
  • 574
  • 0
  • 1.45
  • 1.41
  • 1.26
  • -374
Input
  • 2.18
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1.12
  • 0.00509
  • 0.00312
  • 0.00176
  • 0.000507
  • 0.0235
  • 0.22
  • 0
  • 0.000287
  • 0.0934
  • 0.0285
  • -0.141
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 1.44
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 2.86
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 11.4
  • 0
  • 0
Output
  • 0
  • 0
  • 1.5
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.997
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.698
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 18.6

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Maintenance
B2
Repair
B3
Replacement
B4
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 1.33E+3
  • 46.1
  • 5.05
  • 1
  • 0.408
  • 25.7
  • 574
  • 0
  • 1.45
  • 1.41
  • 37
  • -374
  • 0.0167
  • 0.00000293
  • 8.01E-7
  • 3.96E-7
  • 3.26E-7
  • 0.00056
  • 0.0000639
  • 0
  • 2.66E-7
  • 9.12E-7
  • 0.00297
  • -0.00123
  • 1.4
  • 0.0145
  • 0.000771
  • 0.000332
  • 0.000237
  • 0.0321
  • 0.0831
  • 0
  • 0.000236
  • 0.000892
  • 0.196
  • -0.225
  • 0.0000023
  • 5.85E-8
  • 2.07E-9
  • 3.05E-9
  • 1.03E-9
  • 4.47E-8
  • 3.5E-7
  • 0
  • 2.16E-9
  • 5.58E-8
  • 3.49E-8
  • -7.78E-7
  • 0.00932
  • 0.0000118
  • 0.0000113
  • 0.00000439
  • 0.00000185
  • 0.000239
  • 0.00584
  • 0
  • 7.99E-7
  • 0.00000566
  • 0.000877
  • -0.00166
  • 0.117
  • 0.00558
  • 0.000157
  • 0.0000792
  • 0.0000524
  • 0.00253
  • 0.0156
  • 0
  • 0.0000629
  • 0.000261
  • 0.0102
  • -0.0242
  • 1.46
  • 0.0599
  • 0.00159
  • 0.000644
  • 0.000354
  • 0.0324
  • 0.197
  • 0
  • 0.00066
  • 0.00294
  • 0.145
  • -0.286
  • 93.3
  • 3.37
  • 0.196
  • 0.055
  • 0.0392
  • 1.57
  • 38.6
  • 0
  • 0.0955
  • 2.61
  • 2.92
  • -29.1
  • -0.186
  • 0.000553
  • 0.45
  • 0.000211
  • 0.0000637
  • 0.00391
  • 0.568
  • 0
  • 0.0000319
  • 0.000267
  • 0.0196
  • -0.0671
  • 92.4
  • 3.36
  • 0.195
  • 0.0524
  • 0.0308
  • 1.56
  • 38
  • 0
  • 0.0953
  • 2.61
  • 2.9
  • -28.7
  • 0.541
  • 0.000637
  • 0.00011
  • 0.00241
  • 0.00828
  • 0.00291
  • 0.0631
  • 0
  • 0.0000465
  • 0.000189
  • 0.00634
  • -0.311
  • 92.8
  • 3.36
  • 0.645
  • 0.055
  • 0.0391
  • 1.57
  • 38.6
  • 0
  • 0.0954
  • 2.61
  • 2.93
  • -29.1
  • 0.527
  • 0.02
  • 0.00072
  • 0.000188
  • 0.00014
  • 0.0111
  • 0.0548
  • 0
  • 0.000385
  • 0.000832
  • 0.0408
  • -0.134
  • 36.5
  • 0.117
  • 0.231
  • 0.0393
  • 0.0122
  • 0.834
  • 1.4
  • 0
  • 0.00691
  • 0.0938
  • 3.01
  • -3.25

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Maintenance
B2
Repair
B3
Replacement
B4
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Eco-toxicity - freshwater (ETP-fw) 2
  • 1.82E+3
  • 22.4
  • 1.05
  • 0.615
  • 0.865
  • 53.8
  • 123
  • 0
  • 0.695
  • 23.5
  • 293
  • -162
Human toxicity, cancer effect (HTP-c) 2
  • 4.05E-7
  • 6.44E-10
  • 1.21E-9
  • 3.33E-11
  • 2.11E-11
  • 5.13E-9
  • 8.22E-9
  • 0
  • 4.24E-11
  • 4.15E-10
  • 3.96E-8
  • -1.28E-7
Human toxicity, non-cancer effects (HTP-nc) 2
  • 0.0000146
  • 3.59E-8
  • 5.79E-9
  • 7.47E-10
  • 5.21E-10
  • 3.62E-7
  • 2.54E-7
  • 0
  • 1.03E-9
  • 4.08E-9
  • 0.00000318
  • -0.00000192
Ionizing radiation, human health (IRP) 1
  • 4.17
  • 0.0116
  • 0.004
  • 0.00515
  • 0.000452
  • 0.0679
  • 2.15
  • 0
  • 0.000696
  • 0.0049
  • 0.151
  • -1.33
Land use related impacts/Soil quality (SQP) 2
  • 6E+2
  • 15
  • 0.348
  • 0.509
  • 0.501
  • 12.8
  • 81.7
  • 0
  • 1.47
  • 0.397
  • 66.1
  • -70.4
Particulate Matter emissions (PM) 2
  • 0.00000745
  • 1.06E-7
  • 1.22E-8
  • 2.66E-9
  • 2.5E-9
  • 1.21E-7
  • 3.24E-7
  • 0
  • 9.41E-9
  • 7.59E-9
  • 4.7E-7
  • -0.00000207